5800 and 5900 - Configurations
The new Agilent 5800 and 5900 ICP - OES instruments are available in several configurations:
-
5800 VDV- Vertical Dual View – offers high throughput, and is upgradable on-site to the Synchronous Vertical Dual View configuration if your lab throughput demands increase.
-
5800 RV- Radial View – ideal for labs needing a fast, high-performance radial ICP-OES.
-
5900 SVDV- Synchronous Vertical Dual View – delivers the fastest analyses and the lowest gas usage
Inclusions for each configuration are summarized in the table below:
|
Dichroic Spectral Combiner (DSC) |
O |
✘ |
✓ |
|
Vertically oriented torch |
✓ |
✓ |
✓ |
|
Cool Cone Interface |
✓ |
✘ |
✓ |
|
VistaChip CCD detector |
✓ |
✓ |
✓ |
|
New optical design featuring Freeform optical technology |
✓ |
✓ |
✓ |
|
Oxygen Addition |
O |
O |
✓ |
|
5 Channel Peristaltic pump |
✓ |
✓ |
✓ |
|
2 & 3 port gas control |
O |
O |
✓ |
|
Advanced Valve System (AVS) switching valve |
O |
O |
✓ |
|
IntelliQuant |
✓ |
✓ |
✓ |
|
IntelliQuant Screening |
O |
O |
✓ |
|
ICP Expert v7.5 Base Software |
✓ |
✓ |
✓ |
|
ICP Expert v7.5 Pro Software |
O |
O |
✓ |
|
HP PC, HP Monitor and HP Printer |
✓ |
✓ |
✓ |

|
ICP Expert v7.5* |
|
IntelliQuant |
✓ |
✓ |
|
IntelliQuant Screening |
✘ |
✓ |
|
IntelliQuant pie chart, bar chart and result grid heatmap visualizations |
✘ |
✓ |
|
Early Maintenance Feedback |
✓ |
✓ |
|
Outlier Conditional Formatting |
✓ |
✓ |
|
Neb Alert |
✓ |
✓ |
|
Estimated Detection Limits |
✓ |
✓ |
|
Method Import Wizard |
✓ |
✓ |
|
Plasma Ignition Reminder Dialog |
✓ |
✓ |
|
Advanced Reporting Engine |
✓ |
✓ |
|
Online Help and Learning Center |
✓ |
✓ |
|
Numeric Definition of Off-Peak Marker Positions |
✓ |
✓ |
|
Internal Standard Ratio Chart |
✓ |
✓ |
|
%RSE as a Calibration Validation Parameter |
✓ |
✓ |
|
Column-Based QC |
✓ |
✓ |
|
Rate driven QC |
✘ |
✓ |
|
Third party autosampler support such as Cetac 7400, 7600, ASX520, 560, 1400 and 1600 and EXR8, ESI SC_2,4,8,14 and Micro and AIM 1250 and 360 |
✘ |
✓ |
|
Live export to Microsoft Excel |
✘ |
✓ |
|
Oxygen Injection |
✘ |
✓ |
|
Trend Analysis of argon back pressure to nebulizer and argon emission per sample |
✘ |
✓ |
|
Expanded QC |
✓ |
✓ |
|
IsoMist support |
✓ |
✓ |
|
Enable poly boost on instrument connection |
✓ |
✓ |
|
Inactivity timer to extinguish plasma |
✓ |
✓ |
|
Ability to use SVDV and multiple conditions simultaneously (with number of multiple conditions increased to 8 for all three modes) |
✓ |
✓ |
|
Ability to modify sequence page including sample information (LIMS ID, sample site etc.), lock/unlock rack:tube positions and apply filter column visibility |
✓ |
✓ |
|
Multiple blanks functionality |
✓ |
✓ |
|
Switch off the poly boost, snout purge and park autosampler as end-of-run actions |
✓ |
✓ |
|
Defining detection thresholds and concentration heatmap per element in IntelliQuant |
✓ |
✓ |
|
Decimal places displayed on the IntelliQuant Analysis grid |
✓ |
✓ |
|
Ability to rotate the autosampler diagram and custom rack editor |
✓ |
✓ |
|
ESI prepFASTTM support |
✘ |
✓ |
|
Intelligent Rinse |
✘ |
✓ |
|
Custom Replicates |
✘ |
✓ |
*Please note that ICP Expert v7.5 is compatible with the 5100 and 5110 ICP-OES instruments via a software upgrade.